Run Actions

Table Of Contents

  1. Run Actions
    1. Parameters Description
  2. Step Execution Log
      1. IS FEE N Power Status
      2. IS FEE R Power Status
      3. LFT11396 - ISF PCU N St OverT
      4. LFT11397 - ISF PCU N St OverPriC
      5. LFT11398 - ISF PCU N St FailSecV
      6. LFT11433 - ISF PCU R St OverT
      7. LFT11434 - ISF PCU R St OverPriC
      8. LFT11435 - ISF PCU R St FailSecV
    1. Report PCU Status Signals Plots
      1. ISF PCU N St OverT
      2. LFT11397 - ISF PCU N St OverPriC
      3. LFT11398 - ISF PCU N St FailSecV
      4. LFT11433 - ISF PCU R St OverT
      5. LFT11434 - ISF PCU R St OverPriC
      6. LFT11435 - ISF PCU R St FailSecV

Run Actions

Author Davor
Date 2016-01-27 13:04:51.003 UTC

CheckISFEEHKPCUStatusSignals

  CheckISFEEHKPCUStatusSignals Analyze IS FEE house-keeping
  telemetry, corresponding to PCU Status Signal flags
 
 
  CALL:
          step = ISFEE_Monitor.CheckISFEEHKPCUStatusSignals(pl)
 
  Parameters Description

 
  L Ferraioli 2015-12-21
 
 

Description

Analyze IS FEE house-keeping telemetry corresponding to PCU Status Signals flags

Source Directories

./

Output Directory

ISFEEHKPCUStatusSignals

Parameters Description

ISFEE_Monitor.CheckISFEEHKPCUStatusSignals

Default plist
Key Default Value Options Description
LTPDAPipelineStep.defaultPlist
STEP NAME '' none The name of the pipeline step.
SUBMIT RESULTS 0 none If set to true, the step will submit its results to a repository.
MULTIREPORT 0 none If set to TRUE, will concatenate each execution in the autoReport file, otherwise overwrite
submit
HOSTNAME '' none Database server hostname.
DATABASE '' none Database name.
USERNAME '' none User name to use when connecting to the database. Leave blank to be prompted.
PASSWORD {} [0x0] none Password to use when connecting to the database. Leave blank to be prompted.
CONN [] none Java mysql object.
EXPERIMENT TITLE '' none Title for the submission
EXPERIMENT DESCRIPTION '' none Description of this submission
ANALYSIS DESCRIPTION '' none Description of the analysis performed
QUANTITY '' none Physical quantity represented by the data
KEYWORDS '' none Comma-delimited list of keywords
REFERENCE IDS '' none Comma-delimited list of object IDs
ADDITIONAL COMMENTS '' none Additional comments
ADDITIONAL AUTHORS '' none Additional author names
NO DIALOG 0 none Do not use of the submission form. Mandatory fields must be supplied in the plist.
SINFO FILENAME '' none Path to an XML file containing submission metadata
BINARY 0 none Submit only binary version of the objects
ISFEE_Monitor.CheckISFEEHKPCUStatusSignals.defaultPlist
TIMES [] none Times to split the data on (passed directly to ao/split).

Example

plist('STEP NAME', '', 'HOSTNAME', '', 'DATABASE', '', 'USERNAME', '', 'PASSWORD', cell(0,0), 'CONN', [[]], 'EXPERIMENT TITLE', '', 'EXPERIMENT DESCRIPTION', '', 'ANALYSIS DESCRIPTION', '', 'QUANTITY', '', 'KEYWORDS', '', 'REFERENCE IDS', '', 'ADDITIONAL COMMENTS', '', 'ADDITIONAL AUTHORS', '', 'NO DIALOG', [false], 'SINFO FILENAME', '', 'BINARY', [false], 'SUBMIT RESULTS', [false], 'MULTIREPORT', [false], 'TIMES', [[]])

Step Execution Log

IS FEE N Power Status

LFT71001 IS_FEE_N_Power_Status. 0: Nominal PCU is switched OFF. 1: Nominal PCU is switched ON.	

IS FEE R Power Status

LFT72001 IS_FEE_R_Power_Status. 0: Redundant PCU is switched OFF. 1: Redundant PCU is switched ON.	

LFT11396 - ISF PCU N St OverT

No warning/alerts generated. Normal operation of the nominal unit.	

LFT11397 - ISF PCU N St OverPriC

No warning/alerts generated. Normal operation of the nominal unit.	

LFT11398 - ISF PCU N St FailSecV

No warning/alerts generated. Normal operation of the nominal unit.	

LFT11433 - ISF PCU R St OverT

No warning/alerts generated. Normal operation of the redundant unit.	

LFT11434 - ISF PCU R St OverPriC

No warning/alerts generated. Normal operation of the redundant unit.	

LFT11435 - ISF PCU R St FailSecV

No warning/alerts generated. Normal operation of the redundant unit.	

Report PCU Status Signals Plots

ISF PCU N St OverT

LFT11396 ISF_PCU_N_St_OverT. 0: Normal operation of the nominal unit. 1: Indicates PCU temperature exceeding 50C.	

LFT11397 - ISF PCU N St OverPriC

LFT11397 ISF_PCU_N_St_OverPriC. 0: Normal operation of the nominal unit. 1: Indicates PCU input current exceeding 2.5 A.	

LFT11398 - ISF PCU N St FailSecV

LFT11398 ISF_PCU_N_St_FailSecV. 0: Normal operation of the nominal unit. 1: Indicates output over or under voltage due to PCU internal control loop failure.	

LFT11433 - ISF PCU R St OverT

LFT11433 ISF_PCU_R_St_OverT. 0: Normal operation of the redundant unit. 1: Indicates PCU temperature exceeding 50C.	

LFT11434 - ISF PCU R St OverPriC

LFT11434 ISF_PCU_R_St_OverPriC. 0: Normal operation of the redundant unit. 1: Indicates PCU input current exceeding 2.5 A.	

LFT11435 - ISF PCU R St FailSecV

LFT11435 ISF_PCU_R_St_FailSecV. 0: Normal operation of the redundant unit. 1: Indicates output over or under voltage due to PCU internal control loop failure.	


TOP