Run Actions

Table Of Contents

  1. Run Actions
    1. Parameters Description
  2. Step Execution Log
    1. Report warnings/alarms
      1. IS FEE Digital Control Unit PCB temperature
    2. Report warnings/alarms
      1. IS FEE Analog Control Unit PCB temperature
      2. IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature
      3. IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature
      4. IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature
      5. IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature
      6. IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature
      7. IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature
      8. IS FEE Power Supply Unit temperature
      9. IS FEE Sensing and Actuation Switching Unit temperature
      10. IS FEE Sensing and Actuation Unit temperature (+X1 direction)
      11. IS FEE Sensing and Actuation Unit temperature (-X1 direction)
    3. Plot Unit Temperature
      1. IS FEE Digital Control Unit PCB temperature
      2. IS FEE Analog Control Unit PCB temperature
      3. IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature
      4. IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature
      5. IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature
      6. IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature
      7. IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature
      8. IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature
      9. IS FEE Power Supply Unit temperature
      10. IS FEE Sensing and Actuation Switching Unit temperature
      11. IS FEE Sensing and Actuation Unit temperature (+X1 direction)
      12. IS FEE Sensing and Actuation Unit temperature (-X1 direction)

Run Actions

Author Davor
Date 2016-01-21 15:23:19.603 UTC

CheckISFEEHKTemperature

  CheckISFEEHKTemperature analyze IS FEE house-keeping
  telemetry, corresponding to temperature sensors
 
 
  CALL:
          step = ISFEE_Monitor.CheckISFEEHKTemperature(pl)
 
  Parameters Description

 
  L Ferraioli 2015-01-30
 
 

    Reference page for ISFEE_Monitor.CheckISFEEHKTemperature

Description

Analyze IS FEE house-keeping telemetry corresponding to Temperature sensors

Source Directories

./

Output Directory

ISFEEHKTemperature

Parameters Description

ISFEE_Monitor.CheckISFEEHKTemperature

Default plist
Key Default Value Options Description
LTPDAPipelineStep.defaultPlist
STEP NAME '' none The name of the pipeline step.
SUBMIT RESULTS 0 none If set to true, the step will submit its results to a repository.
MULTIREPORT 0 none If set to TRUE, will concatenate each execution in the autoReport file, otherwise overwrite
submit
HOSTNAME '' none Database server hostname.
DATABASE '' none Database name.
USERNAME '' none User name to use when connecting to the database. Leave blank to be prompted.
PASSWORD {} [0x0] none Password to use when connecting to the database. Leave blank to be prompted.
CONN [] none Java mysql object.
EXPERIMENT TITLE '' none Title for the submission
EXPERIMENT DESCRIPTION '' none Description of this submission
ANALYSIS DESCRIPTION '' none Description of the analysis performed
QUANTITY '' none Physical quantity represented by the data
KEYWORDS '' none Comma-delimited list of keywords
REFERENCE IDS '' none Comma-delimited list of object IDs
ADDITIONAL COMMENTS '' none Additional comments
ADDITIONAL AUTHORS '' none Additional author names
NO DIALOG 0 none Do not use of the submission form. Mandatory fields must be supplied in the plist.
SINFO FILENAME '' none Path to an XML file containing submission metadata
BINARY 0 none Submit only binary version of the objects
ISFEE_Monitor.CheckISFEEHKTemperature.defaultPlist
TIMES [] none Times to split the data on (passed directly to ao/split).
LOW_ALARM_ISF_CUTEMP0 -5 none Low alarm level for IS FEE Digital Control Unit PCB temperature. In [C].
LOW_WARNING_ISF_CUTEMP0 0 none Low warning level for IS FEE Digital Control Unit PCB temperature. In [C].
HIGH_WARNING_ISF_CUTEMP0 40 none High warning level for IS FEE Digital Control Unit PCB temperature. In [C].
HIGH_ALARM_ISF_CUTEMP0 45 none High alarm level for IS FEE Digital Control Unit PCB temperature. In [C].
LOW_ALARM_ISF_CUTEMP1 -5 none Low alarm level for IS FEE Analog Control Unit PCB temperature. In [C].
LOW_WARNING_ISF_CUTEMP1 0 none Low warning level for IS FEE Analog Control Unit PCB temperature. In [C].
HIGH_WARNING_ISF_CUTEMP1 40 none High warning level for IS FEE Analog Control Unit PCB temperature. In [C].
HIGH_ALARM_ISF_CUTEMP1 45 none High alarm level for IS FEE Analog Control Unit PCB temperature. In [C].
LOW_ALARM_ISF_AUTEMP0 -10 none Low alarm level for IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature. In [C].
LOW_WARNING_ISF_AUTEMP0 -5 none Low warning level for IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature. In [C].
HIGH_WARNING_ISF_AUTEMP0 35 none High warning level for IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature. In [C].
HIGH_ALARM_ISF_AUTEMP0 40 none High alarm level for IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature. In [C].
LOW_ALARM_ISF_AUTEMP1 -10 none Low alarm level for IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature. In [C].
LOW_WARNING_ISF_AUTEMP1 -5 none Low warning level for IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature. In [C].
HIGH_WARNING_ISF_AUTEMP1 35 none High warning level for IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature. In [C].
HIGH_ALARM_ISF_AUTEMP1 40 none High alarm level for IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature. In [C].
LOW_ALARM_ISF_AUTEMP2 -10 none Low alarm level for IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature. In [C].
LOW_WARNING_ISF_AUTEMP2 -5 none Low warning level for IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature. In [C].
HIGH_WARNING_ISF_AUTEMP2 35 none High warning level for IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature. In [C].
HIGH_ALARM_ISF_AUTEMP2 40 none High alarm level for IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature. In [C].
LOW_ALARM_ISF_AUTEMP3 -10 none Low alarm level for IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature. In [C].
LOW_WARNING_ISF_AUTEMP3 -5 none Low warning level for IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature. In [C].
HIGH_WARNING_ISF_AUTEMP3 35 none High warning level for IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature. In [C].
HIGH_ALARM_ISF_AUTEMP3 40 none High alarm level for IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature. In [C].
LOW_ALARM_ISF_AUTEMP4 -10 none Low alarm level for IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature. In [C].
LOW_WARNING_ISF_AUTEMP4 -5 none Low warning level for IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature. In [C].
HIGH_WARNING_ISF_AUTEMP4 35 none High warning level for IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature. In [C].
HIGH_ALARM_ISF_AUTEMP4 40 none High alarm level for IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature. In [C].
LOW_ALARM_ISF_AUTEMP5 -10 none Low alarm level for IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature. In [C].
LOW_WARNING_ISF_AUTEMP5 -5 none Low warning level for IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature. In [C].
HIGH_WARNING_ISF_AUTEMP5 35 none High warning level for IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature. In [C].
HIGH_ALARM_ISF_AUTEMP5 40 none High alarm level for IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature. In [C].
LOW_ALARM_TCS_LTPISFEEPCU_TEMP -10 none Low alarm level for IS FEE Power Supply Unit temperature. In [C].
LOW_WARNING_TCS_LTPISFEEPCU_TEMP -5 none Low warning level for IS FEE Power Supply Unit temperature. In [C].
HIGH_WARNING_TCS_LTPISFEEPCU_TEMP 35 none High warning level for IS FEE Power Supply Unit temperature. In [C].
HIGH_ALARM_TCS_LTPISFEEPCU_TEMP 40 none High alarm level for IS FEE Power Supply Unit temperature. In [C].
LOW_ALARM_TCS_ISFEESAUSSU_TEMP -10 none Low alarm level for IS FEE Sensing and Actuation Switching Unit temperature. In [C].
LOW_WARNING_TCS_ISFEESAUSSU_TEMP -5 none Low warning level for IS FEE Sensing and Actuation Switching Unit temperature. In [C].
HIGH_WARNING_TCS_ISFEESAUSSU_TEMP 35 none High warning level for IS FEE Sensing and Actuation Switching Unit temperature. In [C].
HIGH_ALARM_TCS_ISFEESAUSSU_TEMP 40 none High alarm level for IS FEE Sensing and Actuation Switching Unit temperature. In [C].
LOW_ALARM_TCS_LTPISFEESAU_PX1_TEMP -10 none Low alarm level for IS FEE Sensing and Actuation Unit temperature (+X1 direction). In [C].
LOW_WARNING_TCS_LTPISFEESAU_PX1_TEMP -5 none Low warning level for IS FEE Sensing and Actuation Unit temperature (+X1 direction). In [C].
HIGH_WARNING_TCS_LTPISFEESAU_PX1_TEMP 35 none High warning level for IS FEE Sensing and Actuation Unit temperature (+X1 direction). In [C].
HIGH_ALARM_TCS_LTPISFEESAU_PX1_TEMP 40 none High alarm level for IS FEE Sensing and Actuation Unit temperature (+X1 direction). In [C].
LOW_ALARM_TCS_LTPISFEESAU_MX1_TEMP -10 none Low alarm level for IS FEE Sensing and Actuation Unit temperature (-X1 direction). In [C].
LOW_WARNING_TCS_LTPISFEESAU_MX1_TEMP -5 none Low warning level for IS FEESensing and Actuation Unit temperature (-X1 direction). In [C].
HIGH_WARNING_TCS_LTPISFEESAU_MX1_TEMP 35 none High warning level for IS FEE Sensing and Actuation Unit temperature (-X1 direction). In [C].
HIGH_ALARM_TCS_LTPISFEESAU_MX1_TEMP 40 none High alarm level for IS FEE Sensing and Actuation Unit temperature (-X1 direction). In [C].

Example

plist('STEP NAME', '', 'HOSTNAME', '', 'DATABASE', '', 'USERNAME', '', 'PASSWORD', cell(0,0), 'CONN', [[]], 'EXPERIMENT TITLE', '', 'EXPERIMENT DESCRIPTION', '', 'ANALYSIS DESCRIPTION', '', 'QUANTITY', '', 'KEYWORDS', '', 'REFERENCE IDS', '', 'ADDITIONAL COMMENTS', '', 'ADDITIONAL AUTHORS', '', 'NO DIALOG', [false], 'SINFO FILENAME', '', 'BINARY', [false], 'SUBMIT RESULTS', [false], 'MULTIREPORT', [false], 'TIMES', [[]], 'LOW_ALARM_ISF_CUTEMP0', [-5], 'LOW_WARNING_ISF_CUTEMP0', [0], 'HIGH_WARNING_ISF_CUTEMP0', [40], 'HIGH_ALARM_ISF_CUTEMP0', [45], 'LOW_ALARM_ISF_CUTEMP1', [-5], 'LOW_WARNING_ISF_CUTEMP1', [0], 'HIGH_WARNING_ISF_CUTEMP1', [40], 'HIGH_ALARM_ISF_CUTEMP1', [45], 'LOW_ALARM_ISF_AUTEMP0', [-10], 'LOW_WARNING_ISF_AUTEMP0', [-5], 'HIGH_WARNING_ISF_AUTEMP0', [35], 'HIGH_ALARM_ISF_AUTEMP0', [40], 'LOW_ALARM_ISF_AUTEMP1', [-10], 'LOW_WARNING_ISF_AUTEMP1', [-5], 'HIGH_WARNING_ISF_AUTEMP1', [35], 'HIGH_ALARM_ISF_AUTEMP1', [40], 'LOW_ALARM_ISF_AUTEMP2', [-10], 'LOW_WARNING_ISF_AUTEMP2', [-5], 'HIGH_WARNING_ISF_AUTEMP2', [35], 'HIGH_ALARM_ISF_AUTEMP2', [40], 'LOW_ALARM_ISF_AUTEMP3', [-10], 'LOW_WARNING_ISF_AUTEMP3', [-5], 'HIGH_WARNING_ISF_AUTEMP3', [35], 'HIGH_ALARM_ISF_AUTEMP3', [40], 'LOW_ALARM_ISF_AUTEMP4', [-10], 'LOW_WARNING_ISF_AUTEMP4', [-5], 'HIGH_WARNING_ISF_AUTEMP4', [35], 'HIGH_ALARM_ISF_AUTEMP4', [40], 'LOW_ALARM_ISF_AUTEMP5', [-10], 'LOW_WARNING_ISF_AUTEMP5', [-5], 'HIGH_WARNING_ISF_AUTEMP5', [35], 'HIGH_ALARM_ISF_AUTEMP5', [40], 'LOW_ALARM_TCS_LTPISFEEPCU_TEMP', [-10], 'LOW_WARNING_TCS_LTPISFEEPCU_TEMP', [-5], 'HIGH_WARNING_TCS_LTPISFEEPCU_TEMP', [35], 'HIGH_ALARM_TCS_LTPISFEEPCU_TEMP', [40], 'LOW_ALARM_TCS_ISFEESAUSSU_TEMP', [-10], 'LOW_WARNING_TCS_ISFEESAUSSU_TEMP', [-5], 'HIGH_WARNING_TCS_ISFEESAUSSU_TEMP', [35], 'HIGH_ALARM_TCS_ISFEESAUSSU_TEMP', [40], 'LOW_ALARM_TCS_LTPISFEESAU_PX1_TEMP', [-10], 'LOW_WARNING_TCS_LTPISFEESAU_PX1_TEMP', [-5], 'HIGH_WARNING_TCS_LTPISFEESAU_PX1_TEMP', [35], 'HIGH_ALARM_TCS_LTPISFEESAU_PX1_TEMP', [40], 'LOW_ALARM_TCS_LTPISFEESAU_MX1_TEMP', [-10], 'LOW_WARNING_TCS_LTPISFEESAU_MX1_TEMP', [-5], 'HIGH_WARNING_TCS_LTPISFEESAU_MX1_TEMP', [35], 'HIGH_ALARM_TCS_LTPISFEESAU_MX1_TEMP', [40])

Step Execution Log

Report warnings/alarms

IS FEE Digital Control Unit PCB temperature

No warning/alarm generated.	

Report warnings/alarms

IS FEE Analog Control Unit PCB temperature

No warning/alarm generated.	

IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature

No warning/alarm generated.	

IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature

No warning/alarm generated.	

IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature

No warning/alarm generated.	

IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature

No warning/alarm generated.	

IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature

No warning/alarm generated.	

IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature

No warning/alarm generated.	

IS FEE Power Supply Unit temperature

No warning/alarm generated.	

IS FEE Sensing and Actuation Switching Unit temperature

No warning/alarm generated.	

IS FEE Sensing and Actuation Unit temperature (+X1 direction)

No warning/alarm generated.	

IS FEE Sensing and Actuation Unit temperature (-X1 direction)

No warning/alarm generated.	

Plot Unit Temperature

IS FEE Digital Control Unit PCB temperature

IS FEE Analog Control Unit PCB temperature

IS FEE Actuation and Sensing TM1 X-Phi PCB Temperature

IS FEE Actuation and Sensing TM1 Y-Theta PCB Temperature

IS FEE Actuation and Sensing TM1 Z-Eta PCB Temperature

IS FEE Actuation and Sensing TM2 X-Phi PCB Temperature

IS FEE Actuation and Sensing TM2 Y-Theta PCB Temperature

IS FEE Actuation and Sensing TM2 Z-Eta PCB Temperature

IS FEE Power Supply Unit temperature

IS FEE Sensing and Actuation Switching Unit temperature

IS FEE Sensing and Actuation Unit temperature (+X1 direction)

IS FEE Sensing and Actuation Unit temperature (-X1 direction)



TOP