Run Actions

Table Of Contents

  1. Run Actions
    1. Parameters Description
  2. Step Execution Log
      1. Data Status
      2. HK Data Overwritten
      3. OBC Internal Error
      4. DMU Internal Error
      5. TM1 FSM Failure
      6. TM2 FSM Failure
      7. PCU locked/unlocked
      8. PPS Failure
      9. In-quadrature setting for TM1 demodulation signal
      10. In-quadrature setting for TM2 demodulation signal
      11. Plunger bias on TM1
      12. Plunger bias on TM2
      13. OBC or DMU reset
      14. Power ON reset
    1. Report Plots
      1. IS FEE Global Status code
      2. IS FEE Data Status
      3. HK data missed sample
      4. IS FEE OBC Interface Error
      5. IS FEE DMU Interface Error
      6. IS FEE FSM Failure on TM1 and TM2
      7. IS FEE PCU Status
      8. IS FEE PPS Status
      9. IS FEE in-quadrature setting for TM1 and TM2 demodulation signal
      10. IS FEE Plunger Bias Status for TM1 and TM2
      11. IS FEE RT Reset Status
      12. IS FEE Power On Reset Status

Run Actions

Author Davor
Date 2016-01-21 12:29:23.165 UTC

CheckISFEEHKFlags

  CheckISFEEHKFlags Analyze IS FEE house-keeping
  telemetry, corresponding to telemetry flags
 
 
  CALL:
          step = ISFEE_Monitor.CheckISFEEHKFlags(pl)
 
  Parameters Description

 
  L Ferraioli 2015-01-30
 
 

    Reference page for ISFEE_Monitor.CheckISFEEHKFlags

Description

Analyze IS FEE house-keeping telemetry corresponding to telemetry flags

Source Directories

./

Output Directory

ISFEEHKFlags

Parameters Description

ISFEE_Monitor.CheckISFEEHKFlags

Default plist
Key Default Value Options Description
LTPDAPipelineStep.defaultPlist
STEP NAME '' none The name of the pipeline step.
SUBMIT RESULTS 0 none If set to true, the step will submit its results to a repository.
MULTIREPORT 0 none If set to TRUE, will concatenate each execution in the autoReport file, otherwise overwrite
submit
HOSTNAME '' none Database server hostname.
DATABASE '' none Database name.
USERNAME '' none User name to use when connecting to the database. Leave blank to be prompted.
PASSWORD {} [0x0] none Password to use when connecting to the database. Leave blank to be prompted.
CONN [] none Java mysql object.
EXPERIMENT TITLE '' none Title for the submission
EXPERIMENT DESCRIPTION '' none Description of this submission
ANALYSIS DESCRIPTION '' none Description of the analysis performed
QUANTITY '' none Physical quantity represented by the data
KEYWORDS '' none Comma-delimited list of keywords
REFERENCE IDS '' none Comma-delimited list of object IDs
ADDITIONAL COMMENTS '' none Additional comments
ADDITIONAL AUTHORS '' none Additional author names
NO DIALOG 0 none Do not use of the submission form. Mandatory fields must be supplied in the plist.
SINFO FILENAME '' none Path to an XML file containing submission metadata
BINARY 0 none Submit only binary version of the objects
ISFEE_Monitor.CheckISFEEHKFlags.defaultPlist
TIMES [] none Times to split the data on (passed directly to ao/split).

Example

plist('STEP NAME', '', 'HOSTNAME', '', 'DATABASE', '', 'USERNAME', '', 'PASSWORD', cell(0,0), 'CONN', [[]], 'EXPERIMENT TITLE', '', 'EXPERIMENT DESCRIPTION', '', 'ANALYSIS DESCRIPTION', '', 'QUANTITY', '', 'KEYWORDS', '', 'REFERENCE IDS', '', 'ADDITIONAL COMMENTS', '', 'ADDITIONAL AUTHORS', '', 'NO DIALOG', [false], 'SINFO FILENAME', '', 'BINARY', [false], 'SUBMIT RESULTS', [false], 'MULTIREPORT', [false], 'TIMES', [[]])

Step Execution Log

Data Status

No warning/alerts generated. All available data were new data	

HK Data Overwritten

No warning/alerts generated. No samples were missed	

OBC Internal Error

No warning/alerts generated. No OBC error occurred	

DMU Internal Error

No warning/alerts generated. No DMU error occurred	

TM1 FSM Failure

No warning/alerts generated. No TM1 FSM failure occurred	

TM2 FSM Failure

No warning/alerts generated. No TM2 FSM failure occurred	

PCU locked/unlocked

No warning/alerts generated. PCU is locked	

PPS Failure

No warning/alerts generated. No error occurred	

In-quadrature setting for TM1 demodulation signal

No warning/alerts generated. In-quadrature setting switched OFF for TM1 demodulation signal.	

In-quadrature setting for TM2 demodulation signal

No warning/alerts generated. In-quadrature setting switched OFF for TM2 demodulation signal.	

Plunger bias on TM1

No warning/alerts generated. Plunger bias was switched OFF for TM1.	

Plunger bias on TM2

No warning/alerts generated. Plunger bias was switched OFF for TM2.	

OBC or DMU reset

No warning/alerts generated. No OBC or DMU reset occurred.	

Power ON reset

No warning/alerts generated. Power ON reset not occurred.	

Report Plots

IS FEE Global Status code

IS FEE Data Status

HK data missed sample

IS FEE OBC Interface Error

IS FEE DMU Interface Error

IS FEE FSM Failure on TM1 and TM2

IS FEE PCU Status

IS FEE PPS Status

IS FEE in-quadrature setting for TM1 and TM2 demodulation signal

IS FEE Plunger Bias Status for TM1 and TM2

IS FEE RT Reset Status

IS FEE Power On Reset Status



TOP